Cold Room PUF Panel
Technical Specifications Of Puf Panels
THICKNESS : 60,80, 100,125 & 150 mm
SURFACE MATERIAL Gl Pre-Painted Sheet, S.S. Sheet (Grade 304/316), Gl Plain Sheet, Galvanium. (Inside & Outside different metal can be placed as per your requirement).
FLOOR :(A) For Kota stone or Concrete floor, Puf Slab with both side tar felt coated.
(B) For Kota stone or Concrete floor, both side metal surface panel in which each side fits with cam lock and prevent temperature loss.
(C) Aluminium Chequered Plate with Marine Ply.
(D) FRP Cladding on floor
DOOR :
(A) Flush Type : Swing Door with FRP Profile, Imported Hardware, Push Type Gasket & replaceable heater for easy door operation & long life.
Size : 24"x66",30"x72",34"x78",45"x84" (Door Opening W x H)
(A) Over Lap Type: Teak wood frame with metal covering by using heavy duty hardware for better strength
Size : 45"x84",49"x84",54"x84", 60"X90" (Door Opening W x H)
ROOM SIZE :
(A) Length & Width Minimum 1.78 mt and Bigger size 0.146 mt in multiples. As per requirement
(B) Standard Height for 60 mm thickness 2.47 mt, 80 mm-2.51 mt,100 mm-2.55 mt, 125 mm-2.60 mt, 150 mm-2.65 mt. Single Panel Height upto 12 mt and above as per your requirement.
Sr. No. | Parameters | Description |
---|---|---|
1 | Average PUF Density | 40 ± 2 Kg/ cu.mtr/ m³ |
2 | PUF Blowing Agent | 141B (CFC free) |
3 | Insulation Material | Polyurethane foam |
4 | Temperature range | +90°C to -60°C |
5 | Penal Type | Discontinuous type with cam lock |
6 | M.O.C. Of Cam Locks | Cam locks body material HIPS and male latch is made of nylon Glass field with GI sheet reinforcement. Cam-lock panel joints easy assembly and leakage resistant, panel-to-panel joints. |
7 | Type Of Panel Joints | Tongue & Groove Joint with Cam lock and all side rubber gaskets |
8 | Corner Panel Available | 12” X 12” X 134”(Maximum Length) |
9 | Length of wall & ceiling panel | 2032 mm to 6160 mm 80” to 242.5” inch |
10 | Ceiling Suspension items with specs | MS bolt with thermal breaking cap. 4 mm thickness X 80 X 80 mm Aluminum/MS washer plate for load distribution Anchor bolt (MS) hanging bolt with 40 mm washer 2.0 mm thickness Sealing to panel MS road Clamp with an insulated crown. |
11 | Closed cell content | 90 to 95% |
12 | Vapour Permeability | 5.5mg/PASM |
13 | Water Absorption | Less than 2% |
14 | Fire Resistance | FR Grade (Fire Resistance Grade) |
15 | Compressive Strength at 10% Deformation | 0.21 N/ sq.mm (For PUF only) |
16 | Tensile Strength | 0.58 N/ sq.mm (For PUF only) |
17 | Adhesive Strength(Foam to Sheet) | 2.9kg/sq.mtr |
18 | Adhesive Strength (Foam to Sheet) | 2.9 kg /sq.mtr |
19 | Dimension Stability | Less than 2% |
20 | Panel Facing Availability | With Rib or plain on Demand (Ribs are provided for more strength) |
21 | Floor Panel Facing Material | • Puf Panel with both side tarfelt sheet. • Puf Panel with both side 0.5mm GIPP sheet. • Puf Panel with outside GIPP sheet, inside 9 mm thick marine ply with 2 mm thick Aluminium Chequered Plate |
22 | Specification for Colour Coating | A. RAL No. : 9002/9003 or it's nearest B. Indian Standard code Colour Coating : IS 14246 Galvanizing : IS 277 Base Metal : IS 513 C. Organic Coating : Type RMP (Polyester) D. Zinc Coating : 120 GSM E. Top Primer (Thickness in micron 'μ') : 5 +/- 1 μ F. Top Coat (Thickness in micron 'μ') : 20 +/- 1 μ G. Back Primer (Thickness in micron 'μ') : 4 +/- 1 μ H. Back Coat (Thickness in micron 'μ') : 4 +/- 1 μ I. Guard Film (Thickness in micron 'μ') : 40 +/- 3 μ J. Salt Spray Test /Humidity Test : 750 hrs. /1000 hrs. |
23 | Fire Grade of Polyurethane foam | B2 |