BULK MILK CHILLER
ICE MAKE, A leading manufacturer of Industrial and commercial refrigeration equipments, since 2013 by Sanjay Patel ICE MAKE is providing expert cooling solution. We are also offering Bulk Milk Cooler which is used to cool milk at 4°C and to maintain freshness of milk,SOLUTIONS OF BACTERIA FREE MILK STORAGE FOR DAIRY/MILK COLLECTION CENTER.
Cooling & Maintaining Milk Quality At 4° C
The most important part of a collecting centre of milk is the bulk milk cooler (BMC). When the milk is extracted, it is at around 37°C. If the milk continues to remain at room temperature after extraction, bacterial growth will affect the quality of the milk. The BMC is meant to cool the milk to 4°C in a prescribed time. The BMC is available in different shapes and sizes which depending on the amount of milk to be cooled and the system of cooling.
Special Features
- Faster cooling owing to direct expansion.
- Robust design.
- Durable tank made of AISI 304 SS.
- hermetically sealed compressor.
- Digital temp controller.
- Occupy minimum space.
- Energy conscious.
- Designed to be user friendly
Evaporator Cooling Tank For Faster Cooling
In the direct expansion (DX) type, the refrigerant system directly extracts the heat via evaporator (Dimple Jacket) which is the part of the bottom sides of the cooling tank. The tank is insulated to maintain the temperature and is provided with an agitator for uniform distribution and cooling of milk. Efficient evaporator ensures quick and trouble- free cooling and space-saving installation. A high cooling capacity is guaranteed and freezing is prevented for small amounts of milk. The tank is made of stainless steel completely welded and polished. A smooth slope is also provided in milk tank for drain outlet such a way that total milk will drain perfectly.
Insulation
Thickness 60 to 75mm. Insulation Poly Urethane Foam (PUF) CFC free. Density 38 Kg /M3. +/-2 kg, all Body PUF pouring by automatic Imported Machine.Sturer
Gear motor with auto control by timer I.E.:- work 1 minute after every 15 minutesHi Facility To Measure Milk Volume
Dip stick with dip stick chart is provided to measure quantity of milk in the tank.Refrigeration Unit
Designed to work up to 45'c in Indian weather conditionMinimum sound & easy to maintenance
As tank is attached with unit so the sifting cost is free and also protected because of grill cover
Refrigeration system designed such a way that only 3"0 temperature will increase in 12 hours after switch off the working unit at 2'0.
Control Panel
Temperature display with control system MOB for compressor
H.P. / L.P. in selected models
SPPR with under cover voltage protection Overload relay in selected models
Technical Specifications
Description | Unit | MTD-250 | MTD-500 | MTD-1000 | MTD-1500 | MTD-2000 | MTD-3000 | MTD-5000 |
---|---|---|---|---|---|---|---|---|
Tank Capacity | Lt r. | 250 | 500 | 1000 | 1500 | 2000 | 3000 | 5000 |
Dimension - Length | Inch | 35 | 51 | 97 | 98 | 110 | 55 | 110 |
Width | Inch | 28 | 35 | 35 | 43 | 48 | 63 (OD) | 71 (OD) |
Height | Inch | 63 | 63 | 62 | 70 | 71 | 71 | 79 |
No. Of Door | 1 | 1 | 2 | 2 | 1 | 1 | 2 | |
No. Of Agitator | 1 | 1 | 1 | 2 | 1 | 1 | 2 | |
Body Type | Horizontal - Rectangular | Horizontal - Rectangular | Horizontal - Rectangular | Horizontal - Rectangular | Hemi Spherical | Cylindrical – Closed | Cylindrical – Closed | |
Power Input.(Kw) | 1.2 | 2.7 | 4.5 | 5.9 | 6 | 7.8 | 11.8 | |
Power Supply | 1 Ph | 1/3 Ph | 1/3 Ph | 3 Ph | 3 Ph | 3 Ph | 3 Ph | |
Pull Down Time | 5 Hr | 5 Hr | 5 Hr | 5 Hr | 5 Hr | 5 Hr | 5 Hr |